Suntec Energy Systems
Suntec Energy Systems
ISO 9001:2015 Certified
Phase 1, Ahmedabad, Gujarat
SEND SMS
SEND EMAIL

Riello Heavy Oil Burners

We are a leading Wholesale Distributor of modulating heavy oil burner, press n series two stage heavy oil burners, press n eco series two stage heavy oil burners, rn series two stage burners and furnace burners from Ahmedabad, India.

Modulating Heavy Oil Burner

Modulating Heavy Oil Burner
  • Modulating Heavy Oil Burner
Ask For Price
Product Price :Get Latest Price

Product Details:

BrandRiello
Voltage230 V
Frequency50 Hz
PhaseSingle Phase, Three Phase
Available MaterialFiber, MS, SS, Aluminum, Copper
Machine ColorRed
Motor ColorBlack, Silver
Atomised Pressure25
Motor Electrical ProtectionIP 55
Firing Range500 - 5130 kW
ConditionNew

Being a customer oriented organization, we are highly engaged in providing a wide range of Modulating Heavy Oil Burner.
Request
Callback
Yes! I am interested

Press N Series Two Stage Heavy Oil Burners

Press N Series Two Stage Heavy Oil Burners
  • Press N Series Two Stage Heavy Oil Burners
Ask For Price
Product Price :Get Latest Price

Product Details:

Burner Operation ModeTwo stage
Maximum Fuel Temperature140 Degree C
Fuel Pre HeaterYes
Fan TypeCentrifugal with forward blades
maximum Air Temperature60 Degree C
Electrical Supply1/50/230~(+/-10%) Ph/Hz/V
Auxiliary Electrical Supply1/50/230~(+/-10%) Ph/Hz/V
Control Box TypeRMO
Total Electrical Power3.5 kW
Auxiliary Electrical Power0.33 kW
Heaters Electrical Power2.8 kW
Modulation Ratio at Max Output2 Ratio 1
Protection LevelIP 44
Fan Motor Electrical Power0.37 kW
Rated Fan Motor Current2.9 A
Fan Motor Start Current9,5 A
Fan Motor Protection LevelIP 55
Ignition Transformer TypeV1 - V2 230 V - 2x6,5 kV, I1 - I2 2 A - 35 mA
OperationIntermittent (at least one stop every 24 h)
Sound Pressure75 dB (A)
Servomotor TypeLKS 210
Servomotor Run Time5
NCV Heavy Oil11.4 kWh/kg
Viscosity50 (150 with heavy oil kit) (at 50 Degree C) mm 2 /s (cSt)
Pump TypeD67
Pump Delivery65 (20 bar) kg/h
Atomised Pressure20 bar
Working Temperature0/40 Degree C min./max.

The PRESS N series of burners covers a firing range from 85 to 1140 kW and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups or for use in industrial applications, like small or medium plants. Operation is two stage; a servomotor adjust automatically air damper opening, to obtain the right air delivery on both stage. The combustion head, that can be set on the basis of required output, allows optimal performance ensuring good combustion and reducing fuel consumption and is available in two different length to be selected on the basis of specific application requirements. In basic version the burners are supplied for use with heavy oil 7°E viscosity, but they can be supplied with higher viscosity oil with a specific heaters kit. Simplified maintenance is achieved by the slide bar system, which allows easy access to all of the essential components of the combustion head.
Request
Callback


Additional Information:

  • Item Code: PRESS30N
Yes! I am interested
View PDF

Press N Eco Series Two Stage Heavy Oil Burners

Press N Eco Series Two Stage Heavy Oil Burners
  • Press N Eco Series Two Stage Heavy Oil Burners
Ask For Price
Product Price :Get Latest Price

Product Details:

Fan Motor Speed2850 rpm
Voltage230V
PhaseSingle Phase, Three Phase
Frequency50 Hz
Oil Pump Motor Speed1400 rpm
Protection LevelIP X0D (IP 40)
SeriesPRESS
OperationN-Two stage, T/N Three, P/N Modulating, N/ECO Two stage with separated pump
EmissionClass 1 EN267
Standard HeadTC
Extended HeadTL
Flame Control SystemFS1 Standard (1 stop every 24 h), FS2 Continuous working (1 stop every 72 h)

Press N/Eco burner series covers a fi ring range from 171 to 1140 kW and it has been designed for operation with low sulphur fuels. The burners are equipped with a separate low speed pump. They have been designed for use in civil installations of average dimensions, like building areas and large apartment groups or for use in industrial applications, like small or medium plants. Operation is two stage; a servomotor adjust automatically air damper opening, to obtain the right air delivery on both stage. The burners are fi tted with a microprocessor control panel which supplies indication of operation and diagnosis of fault cause. The combustion head, that can be set on the basis of required output, allows optimal performance ensuring good combustion and reducing fuel consumption and is available in two different length to be selected on the basis of specifi c application requirements. In basic version the burners are supplied for use with heavy oil 7°E viscosity, but they can be supplied with higher viscosity oil with a specifi c heaters kit. Simplifi ed maintenance is achieved by the slide bar system, which allows easy access to all of the essential components of the combustion head.

Monoblock forced draught heavy oil burner, two stage operation, made up of:
  • Air suction circuit
  • Fan with forward curved blades
  • Air dampers for air setting controlled by a servomotor
  • Combustion head, fi tted with:
  • stainless steel end cone, resistant to corrosion and high temperatures
  • Ignition electrodes
  • Fl ame stability disk
  • Gears pump for high pressure fuel supply, fi tted with:
  • Fi lter
  • Pressure regulator
  • Connections for installing a pressure gauge and vacuometer
  • Internal by-pass for single pipe installation
  • Valve unit with a double oil safety valve on the output circuit
  • Double fi lter between pump and nozzle
  • Oil preheater provided with chance of a thermometer application for temperature control
  • Installed electrical heaters on pump, nozzle holder, valves assembly
  • Servomotor for air damper regulation
  • Air pressure switch
  • Photocell for fl ame detection
  • Microprocessor-based fl ame control panel, with diagnostic function
  • Flame inspection window
  • Slide bars for easier installation and maintenance
  • Protection fi lter against radio interference

Standard equipment:
  • 2 fl exible hoses for pipe connection
  • 2 gaskets for fl exible hoses
  • 2 nipples for fl exible hoses
  • 1 thermal insulation screen
  • 4 screws for fi xing the burner fl ange to the boiler
  • 2 nozzles (see table of available burner model)
  • 2 extensions for bars (for long head version)
  • Instruction handbook for installation, use and maintenance
  • Spare parts catalogue.
Request
Callback
Yes! I am interested
View PDF

RN Series Two Stage Burners

RN Series Two Stage Burners
  • RN Series Two Stage Burners
Ask For Price
Product Price :Get Latest Price

Product Details:

Voltage230 V
Frequency50 Hz
PhaseSingle Phase, Three Phase
Electric Protection LevelIP 44
Firing Range228 to 1481 kW
OperationTwo stage

The RN series of burners covers have been designed for use in hot or superheater water boilers, hot air or steam generators, diathermic oil boilers. the burners are fitted with an electronic device led panel, which supplies Information about burner working. All necessary components of the hydraulic heavy-oil circuit are assembled in a separate structure, called BAG, for easy and fast installation. forward Optimisation of sound emissions is guaranteed by the use of fan forwarding curved blades and sound deadening material incorporated in the air suction circuit. The elevated performance of the fans and combustion head, guarantee flexibility of use and excellent working. The exclusive design ensures reduced dimensions, simple use and maintenance. A wide range of accessories guarantees elevated working flexibility

Monobloc forced draught heavy on the l burner, two stage operation, made up of:
  • Air suction circuit lined with sound-proofing material
  • Fan with reverse curve blades
  • Air damper for air setting controlled by a servomotor
  • Combustion head, that can be set on the basis of required output
  • Photocell for flame detection
  • Burner safety control box
  • Electronic device to check all burners operational modes (Led Panel)
  • Burner on/off switch
  • Manual 1st and 2nd stage switch
  • Plugs for electrical connections (RN 28-38-50)
  • Flame inspection window
  • Slide bars for easier installation and maintenance
  • Protection filter against radio interference

Bag:
  • Pressure gauge for fuel supply loop
  • Atomising pressure gauge
  • Self-controlling resistances for warming suction filter, delivery filter, valve and pump
  • High and Low point thermostat
  • High point thermostat with reset push-button
  • Loop pressure control switch with burner operation enable (set at 1 bar)
  • Pump
  • Pump motor
  • Pre-purge valve
  • Degassing unit
  • Valve for gas release from degassing unit
  • Comb-filter at delivery
  • Terminal strip
  • Wiring Looms
  • Bag/Burner electrical connection socket
  • Electronic thermostat
  • Heating element Pt100
  • Back pressure valve
  • Comb-filter at pump suction
  • Pre-heater

Standard Equipment:
  • 2 flexible hoses for burner/bag connection (L = 1.3 m)
  • 1 insulation for flexible hoses
  • 2 nipples for flexible hoses
  • 1 insulating screen
  • 4 screws for fixing the burner flange to the boiler
  • Wiring looms for electrical connections (for RN 28-38-50 model)
  • 1 tube for installing BAG on left (for RN 28-38-50 model)
  • 2 nozzles
  • Instruction handbook for installation, use and maintenance
  • Spare parts catalogue
Request
Callback
Yes! I am interested
View PDF

Furnace Burners

Furnace Burners
  • Furnace Burners
Ask For Price
Product Price :Get Latest Price

Product Details:

Make/BrandRiello
Combustion Air Temperature100 Degree C
Minimum Output10 kW
Maximum Output250 kW
Flame Diameter120 mm
Flame Length600 mm
Gas Supply Pressure30 mbar
Air Supply Pressure65 mbar
Weight30 kg (Combustion chamber included)

Specifications
  • Combustion air temperature may range from room temperature to 100 DegreeC.
  • Output Min 10 kW
  • Output Max 250 kW
  • Flame Diameter 120 mm
  • Flame Length 600 mm
  • Gas Supply Pressure 30 mbar
  • Air Supply Pressure 65 mbar
  • Weight (Combustion chamber included) 30 kg

Note

  • Above price is only for burner not included the price for any accessories. Terms & Condition is apply

Request
Callback
Yes! I am interested
X

Explore more products



Reach Us
Anita Nair (Managing Director)
Plot No. 56, Naroda, GIDC Estate
Phase 1, Ahmedabad- 382330, Gujarat, India



Call Us

Share Us

F GT L


Send E-mailSend SMS